# FS SFP-10G-T-100 (Broadcom BCM84891L)
|
||
|
||
Documented, robust — survived the whole poking campaign un-bricked. Honest EEPROM (RJ45/10GBASE-T codes), which is what trips stock ixgbe qualification ([../README.md](../README.md)).
|
||
|
||
References in this directory: [bcm84891l-mdio-commands.md](bcm84891l-mdio-commands.md) (command handler, transcribed), [bcm84891l-sfp-registers.md](bcm84891l-sfp-registers.md) (transport reference, transcribed), and their source PDFs.
|
||
|
||
## SMI transport (I2C→MDIO bridge)
|
||
|
||
PHY at I2C 8-bit **0xAC write / 0xAD read**.
|
||
|
||
| Op | Frames |
|
||
|---|---|
|
||
| Clause-45 write | one I2C write to 0xAC: `[000+DevAD, RegH, RegL, DataH, DataL]` |
|
||
| Clause-45 read | I2C write to 0xAC: `[001+DevAD, RegH, RegL]` → **delay >1 ms** (3 ms proven) → I2C read 2 B from 0xAD |
|
||
|
||
- Single-byte reads see the bridge as inert (returns 0) — the DevAD-prefixed frame + delay is mandatory. This is why early probing wrongly declared 0x56 dead. Treat 0x0000 reads as retry-with-longer-delay: 0 is also the bridge's not-ready signature.
|
||
- Recorded for a future multi-byte firmware transport (mlx5 MCIA shape): read = write `[001+devad,RegH,RegL]` offset_size=1, STOP, >1 ms, read 2 B offset_size=0; write = offset_size=2, addr = devad<<8|RegH, data = `[RegL,DataH,DataL]`.
|
||
|
||
## MDIO command handler
|
||
|
||
Protocol and full verified catalog: [bcm84891l-mdio-commands.md](bcm84891l-mdio-commands.md). Traps:
|
||
|
||
- **SET commands execute stale DATA** — the handler never clears DATA registers; write every parameter register explicitly before any SET.
|
||
- **GETs must be invoked bare** — pre-writing *any* DATA register, not just the documented DATA1 display flag, leaves the handler executing as a no-op with results never written (sentinel pre-fills survived GET_SNR untouched, proven on hardware).
|
||
- **STATUS must never be written** — any user value (0x0000 and 0x0008 both tried) closes the mailbox: the next command is silently ignored until firmware restores it.
|
||
- **PASS cannot prove completion.** The previous command's PASS stays latched while a slow firmware still executes, and until then the DATA registers are firmware scratch — the die temperature turns up in them (0x004E–0x0051 observed as "SNR" and "EEE mode"; the campaign's "anomalous 0x0047" was this same race).
|
||
- **Handler writes during firmware-busy windows wedge the µC permanently** — DATA/CMD writes landing while firmware does post-AN provisioning or training work (a window stretching ~10 s past relink) killed the SMI service four times; reads alone never once. The windowed protocol keeps steady-state writes clear of the temp poll's busy windows; bringup-era writes run unwindowed (they fire pre-AN, where writes have never wedged) and post-AN provisioning exposure remains as the diag path's accepted risk.
|
||
- **Bridge reads carry no fetch identity** — a fetch that outruns the delay leaves the previous transaction's data at 0xAD with no error. A killed host can also leave the pipeline latched a response behind *persistently* (PHY ID served a stuck stale value across processes until driver re-init); every appliance boot clears it by loading the driver, so only bench runs reusing a loaded driver see it, and the identity check at startup dies loudly on it.
|
||
- **Stale reads poisoned the corrected-error channel** — caught with per-register instrumentation: 3.33 reads served 1.147's resident 0x0011 (decoding as exactly 17 errored blocks — the recurring "+17"), SNR DATA values (+21/22), and 1.147 reads served 3.33's 0x8000 (count 16, charged twice by the rollover delta) and the die temperature. Every such burst decodes as a neighbor register. The source is the firmware's own temp poll and the fix is the windowed protocol (firmware-reliability notes): work confined to a fixed window after each observed poll ends the poisoning — reproduced at will by aiming reads at the poll, eliminated by avoiding it.
|
||
- Poll STATUS ~100 ms; frozen up to 2 s during 10GBASE-T training — only run after link-up.
|
||
|
||
## Proven diagnostics
|
||
|
||
| Capability | How | Observed |
|
||
|---|---|---|
|
||
| Per-pair SNR | `CMD_GET_SNR` 0x8030, **invoked bare** (writing the documented DATA1 display flag returns zeros; IEEE 1.133–1.140 never populate — constant 0x8080) | DATA2–5 = SNR A–D ×0.1 dB; ≈ 27–32 dB absolute on bench, 0.1–0.4 dB jitter. 10GBASE-T operating point ≈ 26.5 dB, so margin ≈ value − 26.5. cabletest shows the margin classified green ≥ 3 dB / amber ≥ 1 dB / red below — provisional thresholds until the graded-noise correlation run. **Each training re-converges differently**: back-to-back retrains with identical roles, temperature and noise moved one pair by 3.6 dB (roles pinned, launch power pinned — the convergence itself is the variable, and the two bench modules differ in stability: ≤1.5 dB spread on one, 3.6 dB on the other). A single training's absolute SNR is a weak qualification number; qualification wants median-of-N trainings, live SNR is honest as a within-session tracker |
|
||
| Die temperature | `CMD_GET_CURRENT_TEMP` 0x8031 | ~68–70 °C on bench |
|
||
| Supply rails | `GET_CURRENT_VOLTAGE` 0x802F | 0.8 V and 1.88 V rails, tenths of mV |
|
||
| Error counters | IEEE PCS 3.32/3.33 — block lock, latched errored-block/BER, clear-on-read | The noise-stress error proxy |
|
||
| Retrain on demand | IEEE AN restart `7.0 \|= bit9` | Relinks in ~5–6 s |
|
||
|
||
## Probed configuration states
|
||
|
||
| Item | Command | State |
|
||
|---|---|---|
|
||
| EEE / AutogrEEEn | 0x8008/0x8009 | The famous 0x0047 GET reading was the die temperature in DATA1 (firmware scratch — see reliability notes), not an AutogrEEEn mode; GET 0x8008 is unusable. cabletest forces all-off every boot (SET with explicit params `(0, 0, 0x7A12, 0x480, 0)` + AN restart, proven). The SET programs the advert register directly, so 7.60 reads 0 immediately — bringup verifies it before any AN restart, both µCs quiet; the modules link to each other, so one restart puts both into training, and bringup configures and verifies both before either restart fires (`phy.go`) |
|
||
| EEE wire-truth | arm 0x801A after link-up, read 0x801B | Zero LPI events/duration on idle link; repeat under traffic |
|
||
| Fast retrain | 0x800A (datasheet titles it EMI_MODE; description is fast retrain) | Enabled 10G/5G/2.5G; IEEE 1.147 = 0x0019, count bits zero. Keep enabled; read the 1.147 count per run — a marginal cable that fast-retrains still gets counted |
|
||
| Pair map | 0x8000 | DATA2 = 0x00E4 = identity (A/B/C/D straight through) — MDI wiring verification works |
|
||
| Fault pass-through | 0x800D | 0 = LF/RF pass to the line (0x8011/0x8010 could mask them as IDLE — leave off) |
|
||
| Host interface | 0x802B/0x802D/0x8027 | XFI polarity normal; TX FIR = main tap 0x3C only; MAC/PHY frequency locked; KR/SyncE/USXGMII/WOL disabled; temp warnings off |
|
||
| Jumbo | 0x801C/0x801D | GET 0x801D answers in DATA1 — scratch-prone, unusable — and bringup cannot assume a cable to probe through, so cabletest forces enable every boot (SET 0x801C + AN restart); the running mix's 9018-byte frames are the standing wire truth (`phy.go`). The FS at its 9K option passes them at line rate with zero loss/corrupt |
|
||
| 1588 | 0x8004 | Disabled (engine registers undocumented — see asks below) |
|
||
| Limited reach | 0x8006 | Disabled — its DATA3 "linked in LR mode" bit, the only handler-visible trace of the DSP length estimate, is unavailable without a config change |
|
||
| Master/slave role | IEEE 7.32 bits 15/14 | Left to AN the resolution is a per-training lottery; manual config writes stick exactly and the resolution follows deterministically (7.33.14, no config fault with complementary ends). cabletest forces A master / B slave every boot (`phy.go`) so sessions are measured under identical conditions |
|
||
| Launch power | IEEE 1.130, 1.0.11 | 1.130 reads 0x0003 and is firmware-pinned: host writes to the short-reach bit revert instantly and the value never changes across retrains, so launch power is constant and not host-influenceable. PMA low-power bit clear. The handler catalog has no TX-power command |
|
||
|
||
## Firmware-reliability notes
|
||
|
||
**The firmware is its own mailbox client — the handler is a shared, unarbitrated resource.** Watched read-only on an idle module: CMD sits at 0x0031 (`CMD_GET_CURRENT_TEMP`, bit 15 consumed) and DATA1 tracks the live die temperature (0x4F–0x52 ≈ 79–82 °C under load) — the firmware issues its own temperature command through the same CMD/STATUS/DATA registers the host uses, with no arbitration. Every mystery this explains: temperature appearing in DATA1 (it is that command's output — the campaign's "anomalous 0x0047" included), PASS satisfying a host poll when it belongs to the internal command, and the µC wedges (two writers colliding on CMD/DATA, likeliest when internal management activity spikes after AN events). Any GET whose answer lives in DATA1 is unusable; corroborate through IEEE registers or the wire. The hard rule that stands: write every DATA register explicitly before any SET — the handler executes stale DATA. **The internal poll is not silenceable through the handler**: disabling the temperature warning (SET 0x8032 `(0x007D, 5, 0, 0, 0)` and 0x8034 `(0xFFD8, 5, 0, 0, 0)` — DATA3 = 0 = warning off — both PASS) leaves CMD resident at 0x0031 with DATA1 tracking the die within seconds of the host going quiet; the poll is independent of the warning machinery. GET 0x8033/0x8035 read DATA1–3 = 0 before and after those SETs (DATA4/5 leftover scratch) — DATA1-answer readbacks, unusable as verification either way.
|
||
|
||
**The internal poll's clock, measured on hardware.** One poll every 3.49–4.22 s, regime-dependent but rock-stable within a regime (±15 ms): ≈3.50 s warm and idle, ≈3.70 s, ≈4.01 s cool and idle, ≈4.21 s under continuous host mailbox load — host traffic *defers* the poll, never advances it, and nothing observed brings two polls closer than 3.49 s. The poll is link-independent: it runs straight through an AN restart and the whole retrain without missing a beat. Around each poll's service the bridge serves stale data for ~50 ms: every read returns the last value successfully fetched before the µC went busy (stuck-at-last-fetch, not one-behind), which is exactly how 3.33 inherits 1.147's 0x0011. The window closes *before* the poll is detectable — a CMD read returning the fresh resident 0x0031 is itself proof the µC serviced the fetch, so flip detection doubles as the all-clear.
|
||
|
||
**The windowed protocol (`phy.go`) — contention resolved by time-division.** Since the poll cannot be silenced, the host schedules around it. One goroutine per module owns every transport touch (requests execute one at a time on the loop — nothing else can reach the wire, by construction), and each request is admitted only inside a fixed 3.4 s window following an observed poll (CMD flipping to resident 0x0031, polled at 10 ms); at the cutoff the host goes quiet until the next flip. 3.4 s sits below every observed cadence, so a regime switch mid-run lands harmlessly in vacated time — no prediction, no period tracking, just the last observed flip plus two constants. **Re-lock — no window at assumed phase**: edge detection needs CMD ≠ 0x0031, and normal work leaves it armed (every handler command rewrites CMD), but after a gap with no commands — a diag plus its relink wait, an idle stretch, a poll that skipped its GET because the link bit read down — the resident is 0x0031 and the phase is unknown. Admission then arms first (a bare GET_PAIR_SWAP, resident 0x0000) and anchors only on the true edge that follows, so every window is edge-locked from first contact at boot; bringup pays one phase acquisition per module (~2–4 s). A missing heartbeat free-runs one window rather than stall (never observed — the heartbeat survives retrains). Before re-lock the post-diag window anchored blind on the stale resident, and every ghost observed under windowing sat in exactly that window; with re-lock, ghost-free across all bench diags to date. A poisoned batch is self-consistent and forensically visible: the stuck value clears the link bit (SNR skipped, panel shows "-", the ghost-SNR panic sidestepped) while 3.33 charges the same value as errored blocks (0x0011 → the "+17"); every corrected charge and link-down reading prints its raw 1.1/3.33/1.147 on the console, so events self-attribute — a ghost names its neighbor register, real correction decodes as nothing but itself. Validated on hardware in `~/work/phydiag-work/bcm_phaselock_bench.py`: aiming read bursts at the poll reproduces the poisoning on 100% of polls (the "+17" manufactured on demand); windowed operation ran 2,881 back-to-back batches — 16× the production rate, riding the cutoff — with zero stale values, and the production 1 Hz stream is unperturbed (blackout hides inside natural gaps, worst sample gap ~1.6 s).
|
||
|
||
## ECD — recovered from the OpenBCM SDK, proven on hardware
|
||
|
||
The ECD register mechanism is absent from the handler catalog and the datasheet excerpts here, but the OpenBCM SDK's copper-XGPHY driver (`sdk-6.5.27/src/soc/phy/phy8481.c` `phy_8481_cable_diag` + `phy8481.h`) carries it for the 8483x/8485x/8488x family — and the same SDK drives the identical command-handler registers (1E.0x4005/0x4037/0x4038–3C) as the BCM84891L datasheet, confirming the shared map. Validated on the FS:
|
||
|
||
| Register | Role |
|
||
|---|---|
|
||
| `1E.0x4006` | Control/status. Write under mask {15,14,13,12,10}: bit 15 = run now, bit 14 = run at AN, bit 12 = break link, bit 10 = length in meters (SDK writes value 0x8400 = run now + meters). Bit 11 = busy — poll until clear (SDK allows up to 50 s; observed < 0.5 s) |
|
||
| `1.0xA896` | Verdicts, 4 bits per pair: 1 = OK, 2 = open, 3 = short, 4 = inter-pair short |
|
||
| `1.0xA897–0xA89A` | Per-pair lengths (pairs 1/2, 3/4, 5/6, 7/8), meters |
|
||
|
||
Observed on a plugged, linked, healthy cable: verdicts OK×4 and per-pair lengths of [45, 45, 41, 46] on a ~45 m cable — **meter-accurate with no calibration**, and this ECD reports length for healthy pairs, not just faults, resolving the terminated-far-end concern in [../README.md](../README.md). Caveats:
|
||
|
||
- The run blips the link (PMA 1.1 latch-low catches a drop even with the break-link bit clear) — do not run mid-measurement until the disturbance is characterized.
|
||
- **An interrupted run can wedge the µC's SMI service** (observed after a process died mid-diag): the bridge ACKs I2C but serves 0x0000 for every register at any delay and silently drops MDIO writes — no in-band recovery, not even PMA reset — while the EEPROM path and the trained link keep working. Recovery: a driver unbind/rebind of the port (the SFP re-initialization resets the µC); a reseat would do the same.
|
||
- Fault verdicts (open/short/inter-pair) are unexercised — deliberately: the product is a closed-loop tester, both ends always plugged.
|
||
- Family constraints from the SDK: port must be enabled; unsupported at forced 100M.
|
||
- `bcm_ecd_probe.py` in phydiag-work implements the recipe.
|
||
|
||
## Missing datasheet chapters
|
||
|
||
Chapters the datasheet TOC lists but the excerpts here omit — to source elsewhere:
|
||
|
||
1. The **ECD chapter** — now for confirming bit meanings rather than unblocking.
|
||
2. The **1588 operation chapter**.
|
||
3. Datasheet **§1.20 loopback** (copper line loopback) and **§1.17 EEE/fast-retrain monitoring**.
|
||
4. **Chapter 2 register summary.** The excerpt's TOC names them all.
|