Fibergaga SFP-10G-T-30M (Aquantia AQR)
The documented oracle. RollBall module, PHY ID 0x31c31c13, proven over the i40e oracle path (../../nics/x710/). Its PHY family register reference is vendored in this directory (aquantia-aqr107-aqr109-datasheet.pdf — the AQR107-AQR109 register reference).
Documented registers
| Registers | What |
|---|---|
| 3.E820/3.E821 | PCS Receive Vendor Uncorrected Frame Counter (post-FEC) |
| 3.E840–3.E84E | Corrected Frame N Iteration Counters, N = 1…10 LDPC iterations — the pre-FEC leading indicator (../../open-questions.md §5) |
| 3.E816 | RS Corrected Error Frame Counter (system-side, secondary) |
| 1E.C884 bits 7:0 | Estimated cable length in meters, ±1 m, RO, from the cable diagnostic engine |
| 1E.C800 | Per-pair TDR fault verdicts (open/short/mismatch/cross-pair) |
| 1E.C801–C807 | Distances of the four worst reflections per pair, ±1 m |
| 1E.C880–C883 | Reflection impedance/magnitude |
| PMA 1.133–1.140, PCS 3.32/3.33 | Standard set (../README.md), proven live |
Open bench questions
- Whether
1E.C884is continuously valid on a linked cable or only after an explicit diag run. - The pre-FEC correlation experiment (../../open-questions.md §5) — this module is its instrument.