Measurement lessons

Hard-won rules about measuring correctly. Violating these produces numbers that look plausible and are wrong.

Rate buckets: stamp at read time, never at ticker-fire time

  • direction.capture() stamps each bucket with time.Now() taken immediately after reading the counters — never a timestamp passed in from the sampler ticker.
  • Why: a rate is Δcounters/Δt. The sampler runs a variable delay after its tick, so a tick-time label pairs a right numerator with a wrong denominator — and because E[1/x] > 1/E[x], the error biases the rate upward; it doesn't cancel.
  • Measured: tick-time stamping read 27.55 G / 4.88 Mpps against a true 19.86 G — 35% high. Read-time stamping read within 2%.
  • A 1 s console interval hides it (jitter < 0.2%); a 16 ms panel window exposes it.
  • Never share one timestamp across directions "so buckets share an instant" — nothing needs it, and it reintroduces the skew.

This rule covers the NIC-counter buckets. The per-stream application buckets are a separate system stamped by per-packet MAC RX timestamps (SO_TIMESTAMPING cmsg, rx_filter=ALL as a hard host check); read-time stamping is not a substitute for those — software stamping was tried and cannot reach the needed precision. NICs without all-packet RX timestamping (X710, 82599) fail the host check; see open-questions.md §2.

NIC counters are not monotonic

  • /sys/class/net/*/statistics/* run from boot, not process start, and reset to zero on driver stats resets.
  • In unsigned arithmetic that bites twice: a zero baseline charges the machine's whole lifetime to the run; a backward step underflows now - base to ~2^64.
  • Rule: accumulate only forward motion into a process-local total, then take every baseline from that total — never from a raw reading. Establish all baselines in one place before traffic starts.
  • Debugging tell: when a panel's background disagrees with rows drawn from the same value, suspect two vintages of one counter before a color bug.

Only zero-baseline-loss runs count; small frames measure the host

  • A run counts only when tx frames == rx frames exactly with a clean cable — any nonzero baseline loss masks real cable faults.
  • Small-frame runs are CPU/host-bound, not cable-bound; cable conclusions drawn from them are false.
  • Keep to the default config (hardware.md) and judge from steady state — the first ~5 s is settling transient, not residual error.

Measured performance (AF_PACKET committed path, ice/E810 era)

Config Result
Full size mix, 7 flow-director streams Line rate (10.010.3 Gb/s/dir), ~1.78 Mpps/dir, zero loss including startup
64 B only pps-bound at ~5.4 Mpps/dir (frame generation is the limit, not receive drops) → only ~3.8 Gb/s
AF_XDP experiment (stashed) 64 B TX ~14.5 Mpps/dir; RX ~4 Mpps/dir on AF_PACKET vs ~13.5 with AF_XDP RX
  • RX cannot be parallelized by RSS — hardware RSS can't hash raw ethertypes. Flow-steering by ethertype to distinct queues is what gives multiple NAPI contexts.
  • The AF_XDP experiment delivered per-packet MAC RX stamps via an XDP-metadata kfunc (E810 datapath only; the committed path gets the same stamps via the SO_TIMESTAMPING cmsg). With the test path off the E810 it is parked; its novelty was delivery mechanism and throughput, not the use of hardware stamps.

Dead ends — measured, do not re-attempt without new hardware

The binding constraint was total CPU across ~28 goroutines on 20 threads.

  • Splitting TX senders from RX streams — raises TX but collapses RX (RX scales with queue count, capped at 7 on that NIC).
  • CPU pinning — the Go scheduler beats manual placement; E-cores are poor at TX.
  • Batch sizes above 64 — no gain, worse loss.
  • Chasing the TX sendmmsg busy-spin on ENOBUFS — it only exists when the TX ring is full, which means the wire is the ceiling; recovering that CPU buys no packets. POLLOUT is inert under PACKET_QDISC_BYPASS (skb freed on ENOBUFS, socket always reports writable).

rxnfc / Flow Director programming (ice) — three traps

  1. Mask polarity is inverted vs ethtool -n display. In raw m_u bytes a set bit means "must match": a working "match ethertype, ignore MACs" rule has m_u.ether_spec = dst 00×6, src 00×6, proto ff ff. ethtool -n prints the complement — trusting its display gives an inverted rule that silently matches nothing.
  2. rule_locs sits at offset 188, not sizeof(struct ethtool_rxnfc) (192), on amd64rule_locs[] follows rule_cnt at 188. Reading from 192 yields garbage locations, so existing rules are never found/deleted.
  3. ice rejects RX_CLS_LOC_ANY with ENOSPC — allocate a free location yourself (capacity from ETHTOOL_GRXCLSRLCNT's data; the CLI allocates downward from the top). When a rule inserts but steers nothing, diff the raw bytes of a CLI-made known-good rule against yours.