flamingcow
|
fb4b4596e9
|
Panel rebuilt as the heat matrix: verdict header (ring + newest fault named with its age, cable cell top right), one row per check with NOW / last-90s-at-5s-a-cell / since-reset columns, noise as a blue context lane; history.go keeps the 18-slot wall-time ring (per-class fault deltas, SNR minima, rate verdicts, measuring gray) plus since-reset aggregates and fault ages that clear on reset; noise cycle grid-locked to the shared slot clock so cells never straddle a phase and flicker, presence granted at boot until the first up-phase verdict; check/cross stroked as capsule marks (font has neither), line rate is a pure verdict everywhere, footer is a three-line stat stack beside hold-to-reset; old panel/chip/stat-grid machinery deleted; mockups/ gitignored
|
2026-08-17 12:22:55 -07:00 |
|
flamingcow
|
a9f10d3055
|
Windowed module protocol: every op admitted inside a 3.4s window after the firmware's observed temp poll (cadence 3.5-4.2s measured, stuck-at-last-fetch stale mechanism proven and avoided), acquire/window with panic on dead heartbeat; noise column shows green on/off cycle phase, cable-missing state unchanged
|
2026-08-13 14:04:16 -07:00 |
|
flamingcow
|
979dc7a772
|
BCM module diagnostics replace timestamp probes: bringup forces EEE off and runs ECD (re-run on every reset, re-baselining past its blip), 1 Hz SNR margin + corrected counters on panel and console; X520 bench divergences bypassed and tracked in open-questions
|
2026-08-13 07:10:39 -07:00 |
|
flamingcow
|
2fcab83756
|
Drive a noise cable on the i40e pair, cycling its link down and up since the module PHYs ignore everything softer, and flag its absence beside the error columns
|
2026-08-05 10:49:23 -07:00 |
|