Bridged MDIO reads verify freshness: a late async fetch serves the previous response as the wrong register (observed STATUS 0x0004 as 0.4dB SNR); unchanged-or-zero results re-read bare without re-arming until stable, first read always verified, identify retries against the constant PHY ID
This commit is contained in:
@@ -14,6 +14,7 @@ PHY at I2C 8-bit **0xAC write / 0xAD read**.
|
||||
| Clause-45 read | I2C write to 0xAC: `[001+DevAD, RegH, RegL]` → **delay >1 ms** (3 ms proven) → I2C read 2 B from 0xAD |
|
||||
|
||||
- Single-byte reads see the bridge as inert (returns 0) — the DevAD-prefixed frame + delay is mandatory. This is why early probing wrongly declared 0x56 dead. Treat 0x0000 reads as retry-with-longer-delay: 0 is also the bridge's not-ready signature.
|
||||
- **The fetch is asynchronous and a late one serves the wrong register silently**: the read frame arms a fetch, and if it outruns the delay, reading 0xAD returns the *previous* transaction's response with no error — observed under load even at 3 ms (STATUS 0x0004 served as an SNR DATA read → 0.4 dB). Since the buffer only changes when a fetch lands, a result differing from the previous buffer value is provably fresh; an unchanged (or zero) result must be re-read **bare, without re-arming** — preserving clear-on-read registers — until it stabilizes. cabletest implements this freshness check on every bridged read (`phy.go`).
|
||||
- Recorded for a future multi-byte firmware transport (mlx5 MCIA shape): read = write `[001+devad,RegH,RegL]` offset_size=1, STOP, >1 ms, read 2 B offset_size=0; write = offset_size=2, addr = devad<<8|RegH, data = `[RegL,DataH,DataL]`.
|
||||
|
||||
## MDIO command handler
|
||||
|
||||
+1
-1
@@ -2,7 +2,7 @@
|
||||
|
||||
## Committed tree
|
||||
|
||||
AF_PACKET raw sockets everywhere (`sock.go`); flow-director steering; per-packet-MAC-rx-stamped rate buckets (`SO_TIMESTAMPING` cmsg, `rx_filter=ALL` as a hard host check — nics/README.md for what that demands of the NIC; **temporarily bypassed** in `ts.go` so BCM work can run on the X520, which cannot stamp — the check reports yellow and the panel rates read zero there; restore to fatal for the product NIC); read-time-stamped NIC-counter rates; test interfaces pinned to MTU 9000 with a 9018-byte jumbo in the size mix (the modules' jumbo path is exercised, not assumed); BCM module diagnostics (`phy.go`, over the patched-ixgbe `sff_i2c` debugfs, compound-op framing): bringup identifies both modules and checks EEE off and jumbo on (forcing with an AN restart only on mismatch); the ECD — per-pair verdicts, lengths and pair maps are the length/wiring path — runs through one async path at startup and on every reset, never blocking the UI, with counters re-baselining only after the diag's own link blip so it is never charged to the run; a 1 Hz poller feeds per-pair SNR margin (vs the ≈26.5 dB operating point; green ≥ 3 dB, amber ≥ 1 dB — provisional until the graded-noise run) and the corrected-error set (PCS 3.33 errored blocks/BER, PMA 1.147 fast-retrain count) to the panel and console; framebuffer UI; harness.
|
||||
AF_PACKET raw sockets everywhere (`sock.go`); flow-director steering; per-packet-MAC-rx-stamped rate buckets (`SO_TIMESTAMPING` cmsg, `rx_filter=ALL` as a hard host check — nics/README.md for what that demands of the NIC; **temporarily bypassed** in `ts.go` so BCM work can run on the X520, which cannot stamp — the check reports yellow and the panel rates read zero there; restore to fatal for the product NIC); read-time-stamped NIC-counter rates; test interfaces pinned to MTU 9000 with a 9018-byte jumbo in the size mix (the modules' jumbo path is exercised, not assumed); BCM module diagnostics (`phy.go`, over the patched-ixgbe `sff_i2c` debugfs, compound-op framing, every bridged read staleness-checked — modules/fs/ for the late-fetch hazard): bringup identifies both modules and checks EEE off and jumbo on (forcing with an AN restart only on mismatch); the ECD — per-pair verdicts, lengths and pair maps are the length/wiring path — runs through one async path at startup and on every reset, never blocking the UI, with counters re-baselining only after the diag's own link blip so it is never charged to the run; a 1 Hz poller feeds per-pair SNR margin (vs the ≈26.5 dB operating point; green ≥ 3 dB, amber ≥ 1 dB — provisional until the graded-noise run) and the corrected-error set (PCS 3.33 errored blocks/BER, PMA 1.147 fast-retrain count) to the panel and console; framebuffer UI; harness.
|
||||
|
||||