# FS SFP-10G-T-100 (Broadcom BCM84891L)
Documented, robust — survived the whole poking campaign un-bricked. Honest EEPROM (RJ45/10GBASE-T codes), which is what trips stock ixgbe qualification ([../README.md](../README.md)).
References in this directory: [bcm84891l-mdio-commands.md](bcm84891l-mdio-commands.md) (command handler, transcribed), [bcm84891l-sfp-registers.md](bcm84891l-sfp-registers.md) (transport reference, transcribed), and their source PDFs.
## SMI transport (I2C→MDIO bridge)
PHY at I2C 8-bit **0xAC write / 0xAD read**.
| Op | Frames |
|---|---|
| Clause-45 write | one I2C write to 0xAC: `[000+DevAD, RegH, RegL, DataH, DataL]` |
| Clause-45 read | I2C write to 0xAC: `[001+DevAD, RegH, RegL]`**delay >1 ms** (3 ms proven) → I2C read 2 B from 0xAD |
- Single-byte reads see the bridge as inert (returns 0) — the DevAD-prefixed frame + delay is mandatory. This is why early probing wrongly declared 0x56 dead. Treat 0x0000 reads as retry-with-longer-delay: 0 is also the bridge's not-ready signature.
- Recorded for a future multi-byte firmware transport (mlx5 MCIA shape): read = write `[001+devad,RegH,RegL]` offset_size=1, STOP, >1 ms, read 2 B offset_size=0; write = offset_size=2, addr = devad<<8|RegH, data = `[RegL,DataH,DataL]`.
## MDIO command handler
Protocol and full verified catalog: [bcm84891l-mdio-commands.md](bcm84891l-mdio-commands.md). Traps:
- **SET commands execute stale DATA** — the handler never clears DATA registers; write every parameter register explicitly before any SET.
- **GETs must be invoked bare** — pre-writing *any* DATA register, not just the documented DATA1 display flag, leaves the handler executing as a no-op with results never written (sentinel pre-fills survived GET_SNR untouched, proven on hardware).
- **STATUS must never be written** — any user value (0x0000 and 0x0008 both tried) closes the mailbox: the next command is silently ignored until firmware restores it.
- **PASS cannot prove completion.** The previous command's PASS stays latched while a slow firmware still executes, and until then the DATA registers are firmware scratch — the die temperature turns up in them (0x004E0x0051 observed as "SNR" and "EEE mode"; the campaign's "anomalous 0x0047" was this same race).
- **Handler writes during firmware-busy windows wedge the µC permanently** — DATA/CMD writes landing while firmware does post-AN provisioning or training work (a window stretching ~10 s past relink) killed the SMI service four times; reads alone never once. Every handler write — SETs, GET commands, the ECD trigger — runs only in a quiet window: carrier up and stable ≥ 10 s (`phy.go`).
- **Bridge reads carry no fetch identity** — a fetch that outruns the delay leaves the previous transaction's data at 0xAD with no error.
- Poll STATUS ~100 ms; frozen up to 2 s during 10GBASE-T training — only run after link-up.
## Proven diagnostics
| Capability | How | Observed |
|---|---|---|
| Per-pair SNR | `CMD_GET_SNR` 0x8030, **invoked bare** (writing the documented DATA1 display flag returns zeros; IEEE 1.1331.140 never populate — constant 0x8080) | DATA25 = SNR AD ×0.1 dB; ≈ 2732 dB absolute on bench, 0.10.4 dB jitter. 10GBASE-T operating point ≈ 26.5 dB, so margin ≈ value 26.5. cabletest shows the margin classified green ≥ 3 dB / amber ≥ 1 dB / red below — provisional thresholds until the graded-noise correlation run |
| Die temperature | `CMD_GET_CURRENT_TEMP` 0x8031 | ~6870 °C on bench |
| Supply rails | `GET_CURRENT_VOLTAGE` 0x802F | 0.8 V and 1.88 V rails, tenths of mV |
| Error counters | IEEE PCS 3.32/3.33 — block lock, latched errored-block/BER, clear-on-read | The noise-stress error proxy |
| Retrain on demand | IEEE AN restart `7.0 \|= bit9` | Relinks in ~56 s |
## Probed configuration states
| Item | Command | State |
|---|---|---|
| EEE / AutogrEEEn | 0x8008/0x8009 | The famous 0x0047 GET reading was the die temperature in DATA1 (firmware scratch — see reliability notes), not an AutogrEEEn mode; GET 0x8008 is unusable. cabletest forces all-off every boot (SET with explicit params `(0, 0, 0x7A12, 0x480, 0)` + AN restart, proven) and verifies 7.60 reads 0 after relink (`phy.go`) |
| EEE wire-truth | arm 0x801A after link-up, read 0x801B | Zero LPI events/duration on idle link; repeat under traffic |
| Fast retrain | 0x800A (datasheet titles it EMI_MODE; description is fast retrain) | Enabled 10G/5G/2.5G; IEEE 1.147 = 0x0019, count bits zero. Keep enabled; read the 1.147 count per run — a marginal cable that fast-retrains still gets counted |
| Pair map | 0x8000 | DATA2 = 0x00E4 = identity (A/B/C/D straight through) — MDI wiring verification works |
| Fault pass-through | 0x800D | 0 = LF/RF pass to the line (0x8011/0x8010 could mask them as IDLE — leave off) |
| Host interface | 0x802B/0x802D/0x8027 | XFI polarity normal; TX FIR = main tap 0x3C only; MAC/PHY frequency locked; KR/SyncE/USXGMII/WOL disabled; temp warnings off |
| Jumbo | 0x801C/0x801D | GET 0x801D answers in DATA1 — scratch-prone, unusable — and bringup cannot assume a cable to probe through, so cabletest forces enable every boot (SET 0x801C + AN restart); the running mix's 9018-byte frames are the standing wire truth (`phy.go`). The FS at its 9K option passes them at line rate with zero loss/corrupt |
| 1588 | 0x8004 | Disabled (engine registers undocumented — see asks below) |
| Limited reach | 0x8006 | Disabled — its DATA3 "linked in LR mode" bit, the only handler-visible trace of the DSP length estimate, is unavailable without a config change |
## Firmware-reliability notes
**The firmware is its own mailbox client — the handler is a shared, unarbitrated resource.** Watched read-only on an idle module: CMD sits at 0x0031 (`CMD_GET_CURRENT_TEMP`, bit 15 consumed) and DATA1 tracks the live die temperature (0x4F0x52 ≈ 7982 °C under load), refreshed every ~3.5 s — the firmware issues its own temperature command through the same CMD/STATUS/DATA registers the host uses, with no arbitration. Every mystery this explains: temperature appearing in DATA1 (it is that command's output — the campaign's "anomalous 0x0047" included), PASS satisfying a host poll when it belongs to the internal command, and the µC wedges (two writers colliding on CMD/DATA, likeliest when internal management activity spikes after AN events). The host side keeps exactly one conversation open at a time (one per-module lock around every whole operation, `phy.go`) and confines writes to quiet windows; **contention with the internal client is otherwise unresolved** — a host GET can still be preempted (~10% per command at the temp cadence) and its results replaced. Any GET whose answer lives in DATA1 is unusable; corroborate through IEEE registers or the wire. The hard rule that stands: write every DATA register explicitly before any SET — the handler executes stale DATA.
## ECD — recovered from the OpenBCM SDK, proven on hardware
The ECD register mechanism is absent from the handler catalog and the datasheet excerpts here, but the OpenBCM SDK's copper-XGPHY driver (`sdk-6.5.27/src/soc/phy/phy8481.c` `phy_8481_cable_diag` + `phy8481.h`) carries it for the 8483x/8485x/8488x family — and the same SDK drives the identical command-handler registers (1E.0x4005/0x4037/0x40383C) as the BCM84891L datasheet, confirming the shared map. Validated on the FS:
| Register | Role |
|---|---|
| `1E.0x4006` | Control/status. Write under mask {15,14,13,12,10}: bit 15 = run now, bit 14 = run at AN, bit 12 = break link, bit 10 = length in meters (SDK writes value 0x8400 = run now + meters). Bit 11 = busy — poll until clear (SDK allows up to 50 s; observed < 0.5 s) |
| `1.0xA896` | Verdicts, 4 bits per pair: 1 = OK, 2 = open, 3 = short, 4 = inter-pair short |
| `1.0xA8970xA89A` | Per-pair lengths (pairs 1/2, 3/4, 5/6, 7/8), meters |
Observed on a plugged, linked, healthy cable: verdicts OK×4 and per-pair lengths of [45, 45, 41, 46] on a ~45 m cable — **meter-accurate with no calibration**, and this ECD reports length for healthy pairs, not just faults, resolving the terminated-far-end concern in [../README.md](../README.md). Caveats:
- The run blips the link (PMA 1.1 latch-low catches a drop even with the break-link bit clear) — do not run mid-measurement until the disturbance is characterized.
- **An interrupted run can wedge the µC's SMI service** (observed after a process died mid-diag): the bridge ACKs I2C but serves 0x0000 for every register at any delay and silently drops MDIO writes — no in-band recovery, not even PMA reset — while the EEPROM path and the trained link keep working. Recovery: a driver unbind/rebind of the port (the SFP re-initialization resets the µC); a reseat would do the same.
- Fault verdicts (open/short/inter-pair) are unexercised — deliberately: the product is a closed-loop tester, both ends always plugged.
- Family constraints from the SDK: port must be enabled; unsupported at forced 100M.
- `bcm_ecd_probe.py` in phydiag-work implements the recipe.
## Missing datasheet chapters
Chapters the datasheet TOC lists but the excerpts here omit — to source elsewhere:
1. The **ECD chapter** — now for confirming bit meanings rather than unblocking.
2. The **1588 operation chapter**.
3. Datasheet **§1.20 loopback** (copper line loopback) and **§1.17 EEE/fast-retrain monitoring**.
4. **Chapter 2 register summary.** The excerpt's TOC names them all.