# Current state
|
||||
|
|
|
|||
|
|
## Committed tree
|
|||
|
|
AF_PACKET raw sockets everywhere (`sock.go`), flow-director steering, read-time-stamped rate buckets, framebuffer UI, harness. The zero-copy AF_XDP conversion (both directions, hand-rolled XSK + hand-assembled XDP program, per-frame MAC-stamp buckets via rx metadata) lives uncommitted in `stash@{0}`; it was built for the era when the test path ran on the E810, whose datapath delivers per-packet MAC timestamps. It is an experiment, not a requirement.
|
|||
|
|
|
|||
|
|
`stash@{1}` holds the phydiag campaign: python transport clients (`i40e_aq.py`, `rollball_i40e.py`, `sff.py`), scanners, and a STATUS.md campaign log. Working copies extracted to `~/work/phydiag-work/` during the module work. The knowledge from that campaign is now in these docs; the code should eventually move into the repo properly.
|
|||
|
|
|
|||
|
|
## Hardware in flight
|
|||
|
|
- **Intel X520-DA2 ordered** — replaces the E810 in the box's single PCIe slot. Chosen because ixgbe bit-bangs module I2C from the host (no firmware policy layer), enabling in-product module-PHY diagnostics; see transports.md.
|
|||
|
|
- **Replacement Wiitek (Marvell CUX3610) modules ordered.** Both original units were bricked by register exploration — see modules.md for the trap before ever touching one.
|
|||
|
|
- **In hand** (all copper RJ45 10GBASE-T modules with cloned/lying fiber EEPROMs — see hardware.md; none are actually fiber):
|
|||
|
|
- 2× FS SFP-10G-T-100 (Broadcom BCM84891L, fully documented diagnostics).
|
|||
|
|
- 1× Fibergaga SFP-10G-T-30M (Aquantia, RollBall, the proven oracle module).
|
|||
|
|
- 1× 10Gtek, EEPROM claims SFP-10G-SR — still a copper RJ45 module; filler, not part of the test set.
|
|||
|
|
|
|||
|
|
## Bringup plan when the X520 arrives
|
|||
|
|
1. ixgbe debugfs patch exposing raw I2C transactions (model: the ice `sff_i2c` patch in `kernel/`; ixgbe has no firmware to refuse, so arbitrary framing works).
|
|||
|
|
2. FS/BCM modules first: prove the SMI transport against known-value registers, then the command handler (CMD_GET_SNR vs IEEE registers), on the test cable set.
|
|||
|
|
3. Replacement Wiiteks: IEEE-standard registers only (SNR, latches) unless/until a documented recipe exists for more; the VCT templates in modules.md are candidates for single-shot targeted probes on a sacrificial unit only.
|
|||
|
|
4. Re-derive host tuning on ixgbe (coalescing/ring syntax differs) and re-verify the rxnfc flow-steering code against ixgbe's fdir.
|
|||
|
|
|
|||
|
|
## Open items
|
|||
|
|
- **ECD register chapter**: the one missing document for BCM cable length. FS has been responsive; the narrow ask is "which registers invoke ECD / report the DSP cable-length estimate, and does it run with link up?"
|
|||
|
|
- **Pre-FEC classification** on the Aquantia (3.e820): needs a marginal channel; cabletest's noise stress will provide one once diagnostics are integrated.
|
|||
|
|
- **X710 PTP path-delay length measurement**: viable fallback for linked-cable length (PTP-latch timestamps both ports, same oscillator, 1 ft calibration cancels PHY latency); scoped but unbuilt. Superseded for the product if BCM ECD/DSP length pans out.
|
|||
|
|
- E810 leaves the box when the X520 arrives; the patched ice + `sff_i2c` remains useful only if an E810 returns for read-side work.
|